unify sensor parameter names

This commit is contained in:
andreas 2023-10-31 15:32:08 +01:00
parent f606b78929
commit 9d3390b086
3 changed files with 169 additions and 116 deletions

View File

@ -41,6 +41,52 @@ class GwConfigHandler: public GwConfigDefinitions{
unsigned long getSaltBase(){return saltBase;}
~GwConfigHandler();
bool userChangesAllowed(){return allowChanges;}
template <typename T>
bool getValue(T & target, const String &name, int defaultv=0){
GwConfigInterface *i=getConfigItem(name);
if (!i){
target=(T)defaultv;
return false;
}
target=(T)(i->asInt());
return true;
}
bool getValue(int &target, const String &name, int defaultv=0){
GwConfigInterface *i=getConfigItem(name);
if (!i){
target=defaultv;
return false;
}
target=i->asInt();
return true;
}
bool getValue(long &target, const String &name, long defaultv=0){
GwConfigInterface *i=getConfigItem(name);
if (!i){
target=defaultv;
return false;
}
target=i->asInt();
return true;
}
bool getValue(bool &target, const String name, bool defaultv=false){
GwConfigInterface *i=getConfigItem(name);
if (!i){
target=defaultv;
return false;
}
target=i->asBoolean();
return true;
}
bool getValue(String &target, const String name, const String &defaultv=""){
GwConfigInterface *i=getConfigItem(name);
if (!i){
target=defaultv;
return false;
}
target=i->asString();
return true;
}
private:
unsigned long saltBase=0;
void populateConfigs(GwConfigInterface **);

View File

@ -24,75 +24,86 @@
#ifndef GWIIC_SCL
#define GWIIC_SCL -1
#endif
#define CFG_GET(cfg,name,prefix) \
cfg->getValue(name, GwConfigDefinitions::prefix ## name)
#define CSHT3X(name) \
CFG_GET(config,name,SHT3X)
#define CQMP6988(name) \
CFG_GET(config,name,QMP6988)
#define CBME280(name) \
CFG_GET(config,name,BME280)
class SHT3XConfig{
public:
String tempTransducer;
String humidTransducer;
String tmNam;
String huNam;
int iid;
bool tempActive;
bool humidActive;
long interval;
tN2kHumiditySource humiditySource;
tN2kTempSource tempSource;
bool tmAct;
bool huAct;
long intv;
tN2kHumiditySource huSrc;
tN2kTempSource tmSrc;
SHT3XConfig(GwConfigHandler *config){
tempTransducer=config->getString(GwConfigDefinitions::SHT3XTempName);
humidTransducer=config->getString(GwConfigDefinitions::SHT3XHumidName);
iid=config->getInt(GwConfigDefinitions::SHT3Xiid,99);
tempActive=config->getBool(GwConfigDefinitions::iicSHT3XTemp);
humidActive=config->getBool(GwConfigDefinitions::iicSHT3XHumid);
interval=config->getInt(GwConfigDefinitions::SHT3Xinterval);
interval*=1000;
humiditySource=(tN2kHumiditySource)(config->getInt(GwConfigDefinitions::SHT3XHumSource));
tempSource=(tN2kTempSource)(config->getInt(GwConfigDefinitions::SHT3XTempSource));
CSHT3X(tmNam);
CSHT3X(huNam);
CSHT3X(iid);
CSHT3X(tmAct);
CSHT3X(huAct);
CSHT3X(intv);
intv*=1000;
CSHT3X(huSrc);
CSHT3X(tmSrc);
}
};
class QMP6988Config{
public:
String transducer="Pressure";
String prNam="Pressure";
int iid=99;
bool active=true;
long interval=2000;
bool prAct=true;
long intv=2000;
tN2kPressureSource source=tN2kPressureSource::N2kps_Atmospheric;
float offset=0;
float prOff=0;
QMP6988Config(GwConfigHandler *config){
transducer=config->getString(GwConfigDefinitions::QMP6988PName);
iid=config->getInt(GwConfigDefinitions::QMP6988iid);
active=config->getBool(GwConfigDefinitions::QMP6988act);
interval=config->getInt(GwConfigDefinitions::QMP6988interval);
interval*=1000;
offset=config->getInt(GwConfigDefinitions::QMP6988POffset);
CQMP6988(prNam);
CQMP6988(iid);
CQMP6988(prAct);
CQMP6988(intv);
intv*=1000;
CQMP6988(prOff);
}
};
class BME280Config{
public:
bool pressureActive=true;
bool tempActive=true;
bool humidActive=true;
tN2kTempSource tempSource=tN2kTempSource::N2kts_InsideTemperature;
tN2kHumiditySource humidSource=tN2kHumiditySource::N2khs_InsideHumidity;
tN2kPressureSource pressureSource=tN2kPressureSource::N2kps_Atmospheric;
bool prAct=true;
bool tmAct=true;
bool huAct=true;
tN2kTempSource tmSrc=tN2kTempSource::N2kts_InsideTemperature;
tN2kHumiditySource huSrc=tN2kHumiditySource::N2khs_InsideHumidity;
tN2kPressureSource prSrc=tN2kPressureSource::N2kps_Atmospheric;
int iid=99;
long interval=2000;
String tempXdrName="Temperature";
String humidXdrName="Humidity";
String pressXdrName="Pressure";
float tempOffset=0;
float pressureOffset=0;
long intv=2000;
String tmNam="Temperature";
String huNam="Humidity";
String prNam="Pressure";
float tmOff=0;
float prOff=0;
BME280Config(GwConfigHandler *config){
pressureActive=config->getBool(GwConfigDefinitions::iicBME280Press);
tempActive=config->getBool(GwConfigDefinitions::iicBME280Temp);
humidActive=config->getBool(GwConfigDefinitions::iicBME280Humid);
tempSource=(tN2kTempSource)config->getInt(GwConfigDefinitions::BME280TSource);
humidSource=(tN2kHumiditySource)config->getInt(GwConfigDefinitions::BME280HumSource);
iid=config->getInt(GwConfigDefinitions::BME280iid);
interval=1000*config->getInt(GwConfigDefinitions::BME280interval);
tempXdrName=config->getString(GwConfigDefinitions::BME280TempName);
humidXdrName=config->getString(GwConfigDefinitions::BME280HumidName);
pressXdrName=config->getString(GwConfigDefinitions::BME280PressName);
tempOffset=config->getInt(GwConfigDefinitions::BME280TOffset);
pressureOffset=config->getInt(GwConfigDefinitions::BME280POffset);
CBME280(prAct);
CBME280(tmAct);
CBME280(huAct);
CBME280(tmSrc);
CBME280(huSrc);
CBME280(iid);
CBME280(intv);
intv*=1000;
CBME280(tmNam);
CBME280(huNam);
CBME280(prNam);
CBME280(tmOff);
CBME280(prOff);
}
};
void runIicTask(GwApi *api);
@ -108,38 +119,38 @@ void initIicTask(GwApi *api){
api->addCapability("SHT3X","true");
LOG_DEBUG(GwLog::LOG,"SHT3X configured");
SHT3XConfig sht3xConfig(api->getConfig());
if (sht3xConfig.humidActive && ! sht3xConfig.humidTransducer.isEmpty()){
if (sht3xConfig.huAct && ! sht3xConfig.humidTransducer.isEmpty()){
LOG_DEBUG(GwLog::DEBUG,"SHT3X humidity measure active, adding capability and xdr mappings");
//add XDR mapping for humidity
GwXDRMappingDef xdr;
xdr.category=GwXDRCategory::XDRHUMIDITY;
xdr.direction=GwXDRMappingDef::M_FROM2K;
xdr.field=GWXDRFIELD_HUMIDITY_ACTUALHUMIDITY;
xdr.selector=(int)sht3xConfig.humiditySource;
xdr.selector=(int)sht3xConfig.huSrc;
xdr.instanceMode=GwXDRMappingDef::IS_SINGLE;
xdr.instanceId=sht3xConfig.iid;
xdr.xdrName=sht3xConfig.humidTransducer;
api->addXdrMapping(xdr);
}
if (sht3xConfig.tempActive && ! sht3xConfig.tempTransducer.isEmpty()){
if (sht3xConfig.tmAct && ! sht3xConfig.tName.isEmpty()){
LOG_DEBUG(GwLog::DEBUG,"SHT3X temperature measure active, adding capability and xdr mappings");
//add XDR mapping for humidity
GwXDRMappingDef xdr;
xdr.category=GwXDRCategory::XDRTEMP;
xdr.direction=GwXDRMappingDef::M_FROM2K;
xdr.field=GWXDRFIELD_TEMPERATURE_ACTUALTEMPERATURE;
xdr.selector=(int)sht3xConfig.tempSource;
xdr.selector=(int)sht3xConfig.tmSrc;
xdr.instanceMode=GwXDRMappingDef::IS_SINGLE;
xdr.instanceId=sht3xConfig.iid;
xdr.xdrName=sht3xConfig.tempTransducer;
xdr.xdrName=sht3xConfig.tName;
api->addXdrMapping(xdr);
}
if (sht3xConfig.tempActive || sht3xConfig.humidActive) addTask=true;
if (sht3xConfig.tmAct || sht3xConfig.huAct) addTask=true;
#endif
#ifdef GWQMP6988
api->addCapability("QMP6988","true");
QMP6988Config qmp6988Config(api->getConfig());
if (qmp6988Config.active) {
if (qmp6988Config.prAct) {
LOG_DEBUG(GwLog::LOG,"QMP6988 configured, adding capability and xdr mappings");
addTask=true;
GwXDRMappingDef xdr;
@ -148,7 +159,7 @@ void initIicTask(GwApi *api){
xdr.selector=(int)qmp6988Config.source;
xdr.instanceId=qmp6988Config.iid;
xdr.instanceMode=GwXDRMappingDef::IS_SINGLE;
xdr.xdrName=qmp6988Config.transducer;
xdr.xdrName=qmp6988Config.prName;
api->addXdrMapping(xdr);
}
else{
@ -159,42 +170,42 @@ void initIicTask(GwApi *api){
api->addCapability("BME280","true");
BME280Config bme280Config(api->getConfig());
bool bme280Active=false;
if (bme280Config.pressureActive){
if (bme280Config.prAct){
LOG_DEBUG(GwLog::DEBUG,"BME280 pressure active, adding capability and xdr mapping");
bme280Active=true;
GwXDRMappingDef xdr;
xdr.category=GwXDRCategory::XDRPRESSURE;
xdr.direction=GwXDRMappingDef::M_FROM2K;
xdr.selector=(int)bme280Config.pressureSource;
xdr.selector=(int)bme280Config.prSrc;
xdr.instanceId=bme280Config.iid;
xdr.instanceMode=GwXDRMappingDef::IS_SINGLE;
xdr.xdrName=bme280Config.pressXdrName;
xdr.xdrName=bme280Config.prNam;
api->addXdrMapping(xdr);
}
if (bme280Config.tempActive){
if (bme280Config.tmAct){
LOG_DEBUG(GwLog::DEBUG,"BME280 temperature active, adding capability and xdr mapping");
bme280Active=true;
GwXDRMappingDef xdr;
xdr.category=GwXDRCategory::XDRTEMP;
xdr.direction=GwXDRMappingDef::M_FROM2K;
xdr.field=GWXDRFIELD_TEMPERATURE_ACTUALTEMPERATURE;
xdr.selector=(int)bme280Config.tempSource;
xdr.selector=(int)bme280Config.tmSrc;
xdr.instanceMode=GwXDRMappingDef::IS_SINGLE;
xdr.instanceId=bme280Config.iid;
xdr.xdrName=bme280Config.tempXdrName;
xdr.xdrName=bme280Config.tmNam;
api->addXdrMapping(xdr);
}
if (bme280Config.humidActive){
if (bme280Config.huAct){
LOG_DEBUG(GwLog::DEBUG,"BME280 humidity active, adding capability and xdr mapping");
bme280Active=true;
GwXDRMappingDef xdr;
xdr.category=GwXDRCategory::XDRHUMIDITY;
xdr.direction=GwXDRMappingDef::M_FROM2K;
xdr.field=GWXDRFIELD_HUMIDITY_ACTUALHUMIDITY;
xdr.selector=(int)bme280Config.humidSource;
xdr.selector=(int)bme280Config.huSrc;
xdr.instanceMode=GwXDRMappingDef::IS_SINGLE;
xdr.instanceId=bme280Config.iid;
xdr.xdrName=bme280Config.humidXdrName;
xdr.xdrName=bme280Config.huNam;
api->addXdrMapping(xdr);
}
if (! bme280Active){
@ -231,12 +242,12 @@ void runIicTask(GwApi *api){
int addr=GWSHT3X;
if (addr < 0) addr=0x44; //default
SHT3XConfig sht3xConfig(config);
if (sht3xConfig.humidActive || sht3xConfig.tempActive){
if (sht3xConfig.huAct || sht3xConfig.tmAct){
sht3x=new SHT3X();
sht3x->init(addr,&Wire);
LOG_DEBUG(GwLog::LOG,"initialized SHT3X at address %d, interval %ld",(int)addr,sht3xConfig.interval);
LOG_DEBUG(GwLog::LOG,"initialized SHT3X at address %d, intv %ld",(int)addr,sht3xConfig.intv);
runLoop=true;
timers.addAction(sht3xConfig.interval,[logger,api,sht3x,sht3xConfig,counterId](){
timers.addAction(sht3xConfig.intv,[logger,api,sht3x,sht3xConfig,counterId](){
int rt=0;
if ((rt=sht3x->get())==0){
double temp=sht3x->cTemp;
@ -244,13 +255,13 @@ void runIicTask(GwApi *api){
double humid=sht3x->humidity;
LOG_DEBUG(GwLog::DEBUG,"SHT3X measure temp=%2.1f, humid=%2.0f",(float)temp,(float)humid);
tN2kMsg msg;
if (sht3xConfig.humidActive){
SetN2kHumidity(msg,1,sht3xConfig.iid,sht3xConfig.humiditySource,humid);
if (sht3xConfig.huAct){
SetN2kHumidity(msg,1,sht3xConfig.iid,sht3xConfig.huSrc,humid);
api->sendN2kMessage(msg);
api->increment(counterId,"SHT3Xhum");
}
if (sht3xConfig.tempActive){
SetN2kTemperature(msg,1,sht3xConfig.iid,sht3xConfig.tempSource,temp);
if (sht3xConfig.tmAct){
SetN2kTemperature(msg,1,sht3xConfig.iid,sht3xConfig.tmSrc,temp);
api->sendN2kMessage(msg);
api->increment(counterId,"SHT3Xtemp");
}
@ -266,14 +277,14 @@ void runIicTask(GwApi *api){
if (qaddr < 0) qaddr=0x56;
QMP6988Config qmp6988Config(api->getConfig());
QMP6988 *qmp6988=nullptr;
if (qmp6988Config.active){
if (qmp6988Config.prAct){
runLoop=true;
qmp6988=new QMP6988();
qmp6988->init(qaddr,&Wire);
LOG_DEBUG(GwLog::LOG,"initialized QMP6988 at address %d, interval %ld",qaddr,qmp6988Config.interval);
timers.addAction(qmp6988Config.interval,[logger,api,qmp6988,qmp6988Config,counterId](){
LOG_DEBUG(GwLog::LOG,"initialized QMP6988 at address %d, intv %ld",qaddr,qmp6988Config.intv);
timers.addAction(qmp6988Config.intv,[logger,api,qmp6988,qmp6988Config,counterId](){
float pressure=qmp6988->calcPressure();
float computed=pressure+qmp6988Config.offset;
float computed=pressure+qmp6988Config.prOff;
LOG_DEBUG(GwLog::DEBUG,"qmp6988 measure %2.0fPa, computed %2.0fPa",pressure,computed);
tN2kMsg msg;
SetN2kPressure(msg,1,qmp6988Config.iid,tN2kPressureSource::N2kps_Atmospheric,computed);
@ -286,41 +297,41 @@ void runIicTask(GwApi *api){
int baddr=GWBME280;
if (baddr < 0) baddr=0x76;
BME280Config bme280Config(api->getConfig());
if (bme280Config.tempActive || bme280Config.pressureActive|| bme280Config.humidActive){
if (bme280Config.tmAct || bme280Config.prAct|| bme280Config.huAct){
Adafruit_BME280 *bme280=new Adafruit_BME280();
if (bme280->begin(baddr,&Wire)){
uint32_t sensorId=bme280->sensorID();
bool hasHumidity=sensorId == 0x60; //BME280, else BMP280
if (bme280Config.tempOffset != 0){
bme280->setTemperatureCompensation(bme280Config.tempOffset);
if (bme280Config.tmOff != 0){
bme280->setTemperatureCompensation(bme280Config.tmOff);
}
if (hasHumidity || bme280Config.tempActive || bme280Config.pressureActive)
if (hasHumidity || bme280Config.tmAct || bme280Config.prAct)
{
LOG_DEBUG(GwLog::LOG, "initialized BME280 at %d, sensorId 0x%x", baddr, sensorId);
timers.addAction(bme280Config.interval, [logger, api, bme280, bme280Config, counterId, hasHumidity](){
if (bme280Config.pressureActive){
timers.addAction(bme280Config.intv, [logger, api, bme280, bme280Config, counterId, hasHumidity](){
if (bme280Config.prAct){
float pressure=bme280->readPressure();
float computed=pressure+bme280Config.pressureOffset;
float computed=pressure+bme280Config.prOff;
LOG_DEBUG(GwLog::DEBUG,"BME280 measure %2.0fPa, computed %2.0fPa",pressure,computed);
tN2kMsg msg;
SetN2kPressure(msg,1,bme280Config.iid,bme280Config.pressureSource,computed);
SetN2kPressure(msg,1,bme280Config.iid,bme280Config.prSrc,computed);
api->sendN2kMessage(msg);
api->increment(counterId,"BME280press");
}
if (bme280Config.tempActive){
if (bme280Config.tmAct){
float temperature=bme280->readTemperature(); //offset is handled internally
temperature=CToKelvin(temperature);
LOG_DEBUG(GwLog::DEBUG,"BME280 measure temp=%2.1f",temperature);
tN2kMsg msg;
SetN2kTemperature(msg,1,bme280Config.iid,bme280Config.tempSource,temperature);
SetN2kTemperature(msg,1,bme280Config.iid,bme280Config.tmSrc,temperature);
api->sendN2kMessage(msg);
api->increment(counterId,"BME280temp");
}
if (bme280Config.humidActive && hasHumidity){
if (bme280Config.huAct && hasHumidity){
float humidity=bme280->readHumidity();
LOG_DEBUG(GwLog::DEBUG,"BME280 read humid=%02.0f",humidity);
tN2kMsg msg;
SetN2kHumidity(msg,1,bme280Config.iid,bme280Config.humidSource,humidity);
SetN2kHumidity(msg,1,bme280Config.iid,bme280Config.huSrc,humidity);
api->sendN2kMessage(msg);
api->increment(counterId,"BME280hum");
}

View File

@ -1,6 +1,6 @@
[
{
"name": "iicSHT3XTemp",
"name": "SHT3XtmAct",
"label": "SHT3X Temp",
"type": "boolean",
"default": "true",
@ -11,7 +11,7 @@
}
},
{
"name": "SHT3XTempSource",
"name": "SHT3XtmSrc",
"label": "SHT3X Temp Type",
"type": "list",
"default": "2",
@ -88,7 +88,7 @@
}
},
{
"name": "iicSHT3XHumid",
"name": "SHT3XhuAct",
"label": "SHT3X Humidity",
"type": "boolean",
"default": "true",
@ -99,13 +99,9 @@
}
},
{
"name": "SHT3XHumSource",
"name": "SHT3XhuSrc",
"label": "SHT3X Humid Type",
"type": "list",
"description": "the NMEA2000 source type for the humidity",
"default": "0",
"list":[
{"l":"InsideHumidity","v":"0"},
{"l":"OutsideHumidity","v":"1"},
{"l":"Undef","v":"0xff"}
],
@ -129,7 +125,7 @@
}
},
{
"name": "SHT3Xinterval",
"name": "SHT3Xintv",
"label": "SHT3X Interval",
"type": "number",
"default": 2,
@ -143,7 +139,7 @@
}
},
{
"name": "SHT3XTempName",
"name": "SHT3XtmNam",
"label": "SHT3X Temp XDR",
"type": "String",
"default": "Temp",
@ -154,7 +150,7 @@
}
},
{
"name": "SHT3XHumidName",
"name": "SHT3XhuNam",
"label": "SHT3X Humid XDR",
"type": "String",
"default": "Humidity",
@ -165,7 +161,7 @@
}
},
{
"name": "QMP6988act",
"name": "QMP6988prAct",
"label": "QMP6988 pressure",
"description": "activate the QMP6988 pressure measurement",
"type":"boolean",
@ -190,7 +186,7 @@
}
},
{
"name": "QMP6988interval",
"name": "QMP6988intv",
"label": "QMP6988 Interval",
"type": "number",
"default": 2,
@ -204,7 +200,7 @@
}
},
{
"name": "QMP6988PName",
"name": "QMP6988prNam",
"label": "QMP6988 Pressure XDR",
"type": "String",
"default": "Pressure",
@ -215,7 +211,7 @@
}
},
{
"name":"QMP6988POffset",
"name":"QMP6988prOff",
"label":"QMP6988 Pressure Offset",
"type": "number",
"description": "offset (in pa) to be added to the QMP6988 pressure measurements",
@ -226,7 +222,7 @@
}
},
{
"name": "iicBME280Temp",
"name": "BME280tmAct",
"label": "BME280 Temp",
"type": "boolean",
"default": "true",
@ -237,7 +233,7 @@
}
},
{
"name": "BME280TSource",
"name": "BME280tmSrc",
"label": "BME280 Temp Type",
"type": "list",
"default": "2",
@ -314,7 +310,7 @@
}
},
{
"name":"BME280TOffset",
"name":"BME280tmOff",
"label":"BME280 Temperature Offset",
"type": "number",
"description": "offset (in °) to be added to the BME280 temperature measurements",
@ -325,7 +321,7 @@
}
},
{
"name": "iicBME280Humid",
"name": "BME280huAct",
"label": "BME280 Humidity",
"type": "boolean",
"default": "true",
@ -336,7 +332,7 @@
}
},
{
"name": "BME280HumSource",
"name": "BME280huSrc",
"label": "BME280 Humid Type",
"type": "list",
"description": "the NMEA2000 source type for the humidity",
@ -352,7 +348,7 @@
}
},
{
"name": "iicBME280Press",
"name": "BME280prAct",
"label": "BME280 Pressure",
"type": "boolean",
"default": "true",
@ -363,7 +359,7 @@
}
},
{
"name":"BME280POffset",
"name":"BME280prOff",
"label":"BME280 Pressure Offset",
"type": "number",
"description": "offset (in pa) to be added to the BME280 pressure measurements",
@ -388,7 +384,7 @@
}
},
{
"name": "BME280interval",
"name": "BME280intv",
"label": "BME280 Interval",
"type": "number",
"default": 2,
@ -402,7 +398,7 @@
}
},
{
"name": "BME280TempName",
"name": "BME280tmNam",
"label": "BME280 Temp XDR",
"type": "String",
"default": "Temp",
@ -413,7 +409,7 @@
}
},
{
"name": "BME280HumidName",
"name": "BME280huNam",
"label": "BME280 Humid XDR",
"type": "String",
"default": "Humidity",
@ -424,7 +420,7 @@
}
},
{
"name": "BME280PressName",
"name": "BME280prNam",
"label": "BME280 Pressure XDR",
"type": "String",
"default": "Pressure",